HomeMy WebLinkAbout256 CAJETAN ST - DISCLOSURES - 10/15/2014Date of Test: 10/15/2014
Customer: FIR Development
Fort Collins, CO
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
BUILDING LEAKAGE TEST
GS Services
2000 South College Ave.
Suite 308
Fort Collins, CO 80525
Test File: FIR Dev 256 Cajatan BD
Technician: Paul Higman
Project Number:
Building Address: 256 Cajatan
Fort Collins, CO 80524
962 CFM50 (+1- 1.7 %)
2.22 ACH50
52.9 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 35.2 (+/- 12.8 %)
Exponent (n) = 0.846 ( +/- 0.035 )
Correlation Coefficient = 0.99892
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 54.3 CFM
0.13 ACH
2. Estimated Design Infiltration Rate: Winter: 87.6 CFM Summer: 58.1 CFM
0.20 ACH 0.13 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Digitally signed by:
Paul
Paul Higman
' DN: CN = Paul
Higman"Hagman C= US
Date. 2014.10.22 07:
214:46-06'00'
No Text
No Text
No Text