Loading...
HomeMy WebLinkAbout256 CAJETAN ST - DISCLOSURES - 10/15/2014Date of Test: 10/15/2014 Customer: FIR Development Fort Collins, CO Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST GS Services 2000 South College Ave. Suite 308 Fort Collins, CO 80525 Test File: FIR Dev 256 Cajatan BD Technician: Paul Higman Project Number: Building Address: 256 Cajatan Fort Collins, CO 80524 962 CFM50 (+1- 1.7 %) 2.22 ACH50 52.9 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 35.2 (+/- 12.8 %) Exponent (n) = 0.846 ( +/- 0.035 ) Correlation Coefficient = 0.99892 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 54.3 CFM 0.13 ACH 2. Estimated Design Infiltration Rate: Winter: 87.6 CFM Summer: 58.1 CFM 0.20 ACH 0.13 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higman ' DN: CN = Paul Higman"Hagman C= US Date. 2014.10.22 07: 214:46-06'00' No Text No Text No Text