Loading...
HomeMy WebLinkAbout2159 SCARECROW RD - DISCLOSURES - 9/16/2014J BUILDING LEAKAGE TEST GS"iSkbrv' es Date of Test: 9/16/2014 Test File: Bellisimo Construction - 2159 Scarecrow Road - Unit B - BD 2 Customer: Bellisimo Construction Technician: GS Services Project Number: Fort Collins, CO 80526 Building Address: Unit B 2159 Scarecrow Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1085 CFM50 (+/- 1.4 %) (50 Pa = 0.2 w.c.) 4.99 ACH50 0.8311 CFM50/ft2 floor area 2. Leakage Areas: 82.0 in2 (+/- 5.9 %) Canadian EgLA @ 10 Pa 36.5 in2 ( +/- 9.5 %) LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 40.0 ( +/-15.1 %) Exponent (n) = 0.844 ( +/- 0.040 ) Correlation Coefficient = 0.99214 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 37.5 CFM 0.17 ACH 2. Estimated Design Infiltration Rate: Winter: 60.5 CFM Summer: 40.1 CFM 0.28 ACH 0.18 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Paul Digjtally signed by: Paul Higman DN: CN = Paul Higman C = US Hi Dafe:2014.09.1706:41:09- 9man /0700. No Text . �� �" '..�ij GS Ser�tices ��-- BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 9/16l2014 Test File: Bellisimo Construction- 2159 Scarecrow Road - Unit B-BD 2 Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) 77.0 80.0 Data Points-Data Entered Manually Nominal BaselineAdjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -4.6 n/a n/a -60.7 -56.3 40.8 1159 1162 -3.1 Ring A -55.6 -51.2 37.3 1110 1113 0.6 Ring A -50.9 -46.5 32.7 1041 1044 2.3 Ring A -45.5 -41.1 25.9 930 933 1.5 Ring A -40.7 -36.3 216.3 871 873 5.5 Ring B -36.1 -31.7 136.8 694 696 -5.7 Ring B -31.6 -27.2 112.9 631 633 -2.5 Ring B -26.8 -22.4 80.0 532 533 -3.2 Ring B -20.7 -16.3 51.8 429 430 2.1 Ring B -4.2 n/a n/a Deviations from Standard CGSB-Test Parameters None . � Y l '�. 1 GS Serxlc�S _,�=----- BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 9/16/2014 Test File: Bellisimo Construction- 2159 Scarecrow Road-Unit B-BD 2 Comments House WRT Garage=-45.1 pa