HomeMy WebLinkAbout2974 DENVER DR - DISCLOSURES - 8/16/2014i rvice
Date of Test: 8/16/2014
Customer: Journey Homes
7251 W 20th Street
L-200
Greeley, CO 80634
Phone: 970-449-1612
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
4. Test Settings:
5. Accuracy Level
BUILDING LEAKAGE TEST
GS Servies
2000 S. College Ave
suite 308
Fort Collins, CO 80525
Test File: Journey Homes 2974 Denver BD
Technician: Paul Higman
Project Number:
Building Address: 2974 Denver
Fort Collins, CO 80525
1532 CFM50 (+/- 1.2 %)
3.69 ACH50
84.3 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 222.3 (+/- 8.9 %)
Exponent (n) = 0.493 ( +/- 0.025 )
Correlation Coefficient = 0.99846
Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 86.6 CFM
0.21 ACH
2. Estimated Design Infiltration Rate: Winter: 139.6 CFM Summer: 92.6 CFM
0.34 ACH 0.22 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Pau I Digitally signed by:
PaulfHigman
;DN/: CN =Paul
Higman,f "..�anC=US
` paste: 2014.08.26
15.03:16-06-00'