Loading...
HomeMy WebLinkAbout2974 DENVER DR - DISCLOSURES - 8/16/2014i rvice Date of Test: 8/16/2014 Customer: Journey Homes 7251 W 20th Street L-200 Greeley, CO 80634 Phone: 970-449-1612 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: 4. Test Settings: 5. Accuracy Level BUILDING LEAKAGE TEST GS Servies 2000 S. College Ave suite 308 Fort Collins, CO 80525 Test File: Journey Homes 2974 Denver BD Technician: Paul Higman Project Number: Building Address: 2974 Denver Fort Collins, CO 80525 1532 CFM50 (+/- 1.2 %) 3.69 ACH50 84.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 222.3 (+/- 8.9 %) Exponent (n) = 0.493 ( +/- 0.025 ) Correlation Coefficient = 0.99846 Test Standard: RESNET Multi -Point Test Test Mode: Depressurization Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 86.6 CFM 0.21 ACH 2. Estimated Design Infiltration Rate: Winter: 139.6 CFM Summer: 92.6 CFM 0.34 ACH 0.22 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Pau I Digitally signed by: PaulfHigman ;DN/: CN =Paul Higman,f "..�anC=US ` paste: 2014.08.26 15.03:16-06-00' No Text No Text No Text