Loading...
HomeMy WebLinkAbout607 STONEY BROOK RD - DISCLOSURES - 5/18/2012 (2)0 C BUILDING LEAKAGE TEST Thermal Concepts 6617 S. College Ave Fort Collins, CO 80525 Phone: 970-223-7090 Date of Test: 5-18-12 Test File: Journry Homes 607 Stoney Brook BD Customer: Journey Homes Phone Test. Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Minneapolis Leakage Ratio: 4. Building Leakage Curve: 5. Test Settings: Technician: Paul Higman Building Address: 607 Stoney Brook Fort Collins, CO 80525 790 CFM (+/- 0.9 %) 2.89 ACH 0.35 CFM per ft2 floor area 71.0 in2 (+/- 4.0 %) Canadian EgLA @ 10 Pa 34.9in2(+/-6.6%)LBLELA@4Pa 0.00 CFM50 per ft2 surface area Flow Coefficient (C) = 44.3 (+! 10.6 %) Exponent (n) = 0.736 ( +/- 0.029 ) Correlation Coefficient = 0.99697 Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door, S/N 9876 Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 31.2 CFM 0.11 ACH 2. Estimated Design Infiltration Rate: Winter: 58.9 CFM 0.22 ACH Summer: 33.5 CFM 0.12 ACH 3. Recommended Whole Building Mechanical 52.7 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 5-18-12 Test File: Journry Homes 607 Stoney Brook BD Building Conditions Inside Temperature: 74 deg F Heating Fuel: Gas Outside Temperature: 75 deg F Heating Fuel Cost: # of Stories 2.0 Heating Efficiency: Heating Degree Days: 6020 Wind Shield: M Cooling Fuel Cost: # of Occupants Cooling SEER: Cooling Degree Days: 287 # of Bedrooms: 3.0 Volume: 16369 ft3 Ventilation Weather Factor: 0.87 Surface Area: Energy Climate Factor: 17.0 Floor Area: 2268 ft2 Design Winter Wind Speed: 9.0 mph Design Winter Temp Diff: 69 deg F Design Summer Wind Speed: 7.0 mph Design Summer Temp Diff: 16 deg F Comments BUILDING LEAKAGE TEST Page 3 Date of Test: 5-18-12 Test File: Journry Homes 607 Stoney Brook BD Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Std Dev (Pa) -0.7 n/a +/- 0.00 -50.4 179.0 793 794 0.2 Ring B -45.8 150.6 728 729 -1.2 Ring B -40.1 126.6 668 669 -0.0 Ring B -34.7 106.1 612 613 2.0 Ring q -30.6 86.5 553 554 1.1 Ring B -25.0 59.4 459 459 -2.5 Ring B 0.3 n/a +/- 0.00 I