HomeMy WebLinkAbout607 STONEY BROOK RD - DISCLOSURES - 5/18/2012moo lot,
Contractor
Services
-
Uniform Energy Rating System
5A" R4&ff
607 Stoney Brook Rd
607 Stoney Brook Rd
Fort Collins, CO 80525
5 Stars Plus
Confirmed Rating
Energy Efficient
1 Star
1 Star Plus
2 Stars
2 Stars Plus
3 Stars
3 Stars Plus
4 Stars
4 Stars Plus
5 Stars
5 Stars Plus
500-401
400.301
300-251
250-201
200-151
150-101
100-91 1
90-88
1 85-71
70 or Less
HERS Index:
Conditioned Area: 2268 sq. ft. HouseType: Single-family detached
Conditioned Volume: 16369 cubic ft. Foundation: More than one type
Bedrooms: 3
Mechanical Systems Features
Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE.
Water Heating: Conventional, Electric, 0.95 EF, 50.0 Gal.
Dud Leakage to Outside: 34.00 CFM.
Ventilation System: Exhaust Only: 85 cfm, 24.0 watts.
Programmable Thermostat: Heating: No Cooling: No
wilding Shell Features
Ceiling Flat: R-38 Exposed Floor. R-39
Vaulted Ceiling: R-38 Window Type: U:0.34,SHGC:0.31
Above Grade Walls: R-15 Infiltration:
Foundation Walls: R-0.0, R-11.0 Rate: Htg: 790 Cig: 790 CFM50
Slab: R-0.0 Edge, R-0.0 Under Method: Blower door test
Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor. 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater: Paul Higman
Rating Date: 5-18-12
Rating Ordered For. Journey Homes
Estimated Annual Energy Cost
Confirmed Rating
Use MMBtu Cost Percent
Heating 56.5 $374
24%
Cooling 0 $0
0%
Hot Water 13.3 $330
21%
Lights/Appliances 26.3 $650
42%
Photovoltaics -0.0 $-0
-0%
Service Charges $198
13%
Total $1553
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 Intemational Energy Conservation Code
14 Digitally signed
- by: Paul
Masco Home Services Higman
Pau.lr DN; CN=Paul
2339 Beville Rd
Higman C =AD
Daytona Beach, FL. 32119 — r
O = Thermal
concepts
386-3042200 Signatu H i g m
n Date: 2012.05.
-
tats:os:oz-
}
re not 1' /
moo
Reason: I am
verified! i
thsd G°ment