HomeMy WebLinkAbout2050 SCARECROW RD - DISCLOSURES - 7/2/2014Date of Test: 7/2/2014
Customer: H & O Homes
Fort Collins, CO
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
BUILDING LEAKAGE TEST
GS Services
2000 S. College Ave
#308
Fort Collins, CO 80525
Test File: Hupp Const 2050 Sc
Technician: Paul Higman �!
Project Number:
Building Address: 2050 Scarecrow
Fort Collins, CO 80525
2077 CFM50 (+!- 0.9 %)
3.62 ACH50
114.2 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 149.2 (+/- 6.6 %)
Exponent (n) = 0.673 ( +/- 0.018 )
Correlation Coefficient = 0.99962
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 98.4 CFM
0.17 ACH
2. Estimated Design Infiltration Rate: Winter: 139.2 CFM Summer: 102.1 CFM
0.24 ACH 0.18 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 7/2/2014 Test File Hupp Const 2050 Scarecrow -BD
Building Information Location Climate Information
Volume
Surface Area
Floor Area
34431
3498
Height
10
# of Bedrooms
3
# of Occupants
Year of Construction
2014
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel
Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Ventilation Weather Factor
0.67
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
19028-6
911=009
No Text
No Text