HomeMy WebLinkAbout2250 BAR HARBOR DR - DISCLOSURES - 5/31/2014 (19)ftwwsll_�' r � Date of Test: 5/31/2014 Customer: Journey Homes Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 S. College Ave #308 Fort Collins, CO 80525 Test File: Journey Homes 2250 Bar Harbor -1784- Confirmed Technician: Paul Higman Project Number: Building Address: 2250 Bar Harborkf A(Z Fort Collins, CO 80524 1359 CFM50 (+/-1.9 %) 2.66 ACH50 74.7 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 75.3 (+/- 13.7 %) Exponent (n) = 0.739 ( +/- 0.038 ) Correlation Coefficient = 0.99836 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 76.8 CFM 0.15 ACH 2. Estimated Design Infiltration Rate: Winter: 123.8 CFM Summer: 82.2 CFM 0.24 ACH 0.16 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul Paul Higmen /� =/UCN S = Paul Higmen Higma�D e: 2014.06.03 13: `:1r.42-06'00• (�) i y" v 0 5-�Z �5��� BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 5/31/2014 Test File: Journey Homes 2250 Bar Harbor-1784-Confirmed Building Information Location Climate Infortnation Volume . 30621 Ventilation Weather Factor 0.87 SurFaceArea Energy Climate Factor 17.00 FloorArea 3162 Heating Degree Days 6128 Height 18 Cooling Degree Days 297 #of Bedrooms 3 Design Winter Wind Speed 7.3 mph #of Occupants Design Summer Wind Speed 9.4 mph Year of Construction 2014 Design Winter Temp Diff 73 deg F Wind Shield M Design Summer Temp Diff 15 deg F Heating and Cooling Cost and Efficiency Infortnation Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3(110� Default Micromanometer Energy Conservatory DG700 13� yoo �z� �S� BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 5/31/2014 Test File: Journey Homes 2250 Bar Harbor-1784-Confirmed Depressurization Test: Environmental Data Indoor Temperature(/�°F) Outdoor Temperature(A°F) Altitude(ft) 72.0 79.0 4950.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) %Error Configuration -1.8 n/a n/a -60.1 -58.1 62.8 1431 1522 0.2 Ring A -55.0 -53.0 55.0 1341 1427 0.5 RingA -50.1 -48.1 47.4 1248 1328 0.5 Ring A -45.1 �3.1 40.5 1155 1229 0.8 RingA -40.7 -38.8 34.5 1068 1136 1.0 Ring A -35.2 -33.3 25.6 924 983 -2.2 RingA -30.2 -28.3 189.2 815 867 -2.7 Ring B -25.0 -23.1 145.7 716 762 -0.6 Ring B -20.5 -18.6 112.5 630 670 2.7 Ring B -2.1 n/a n/a TimeAveraging Period: 10 Deviations from Standard RESNET Multi-Point Test-Test Parameters None (�j(�-(JU `S �Z w �5��� BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 5/31/2014 Test File: Joumey Homes 2250 Bar Harbor-1784-Confirmed Comments House WRT Garage=-46.8pa � ��06 5�v