Loading...
HomeMy WebLinkAbout2920 JOSEPH DR - DISCLOSURES - 4/25/2014let v� r Date of Test: 4/25/2014 Customer: Journey Homes 7251 W 20th Street L-200 Greeley, CO 80634 Phone: 970-449-1612 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Area: 3. Building Leakage Curve: BUILDING LEAKAGE TEST GS Services 2000 South College Ave Suite 308 Fort Collins, CO 80525 Test File: Journey Homes 2920 Joseph Dr- BD Technician: Paul Higman Project Number: Building Address: 2920 Joseph Dr Fort Collins, Colorado 80525 1260 CFM50 (+/- 2.2 %) 3.23 ACH50 69.3 in2 LBL ELA @ 4 Pa Flow Coefficient (C) = 33.0 (+/- 16.2 %) Exponent (n) = 0.931 ( +/- 0.045 ) Correlation Coefficient = 0.99855 4. Test Settings: Test Standard: RESNET Multi -Point Test Test Mode: Depressurization 5. Accuracy Level Standard Level of Accuracy Test Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 71.2 CFM 0.18ACH 2. Estimated Design Infiltration Rate: Winter: 114.8 CFM Summer: 76.2 CFM 0.29 ACH 0.20 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed Paul bye: Paul Higman //DNCN = Paul H ig m a n�Hig/nan c = US D e.2014.04.28 :28:25-06'00' Cis2 _CAS BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4/25/2014 Test File: Journey Homes 2920 Joseph Dr- BD Building Information Volume 23382 Surface Area Floor Area 2445 Height 18 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 G$ SETTS BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4/25/2014 Test File: Journey Homes 2920 Joseph Dr- BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) Altitude (ft) 69.0 71.0 4950.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Building Pressure Building Pressure Pressure (Pa) (Pa) (Pa) -1.9 n/a n/a -60.5 -58.5 52.4 -55.3 -53.3 44.0 -50.7 -48.8 39.3 -45.0 43.0 31.7 40.3 -38.3 26.1 -36.1 -34.1 193.9 -30.6 -28.7 134.8 -25.8 -23.9 92.6 -20.8 -18.9 60.2 -2.0 n/a n/a Time Averaging Period: 10 None Nominal Adjusted Flow Flow Fan (cfm) (cfm) % Error Configuration 1310 1426 -2.3 Ring A 1203 1310 -2.2 Ring A 1139 1240 0.7 Ring A 1025 1116 1.8 Ring A 932 1015 3.1 Ring A 825 898 1.6 Ring B 689 750 -0.0 Ring B 572 623 -1.6 Ring B 462 503 -1.0 Ring B Deviations from Standard RESNET Multi -Point Test - Test Parameters e`-»�'��, . G,�.��'�S gUILDING LEAKAGE TEST Page 4 of 4 Date of Test:4/25/2014 Test File: Journey Homes 2920 Joseph Dr- BD Comments House WRT Garage=-47.1 pa