HomeMy WebLinkAbout508 BANNOCK ST - DISCLOSURES - 3/12/2014 (3)Date of Test: 3-12-14 Customer: Encore Homes Windsor, CO 80550 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: BUILDING LEAKAGE TEST Thermal Concepts P.O. Box 270066 Fort Collins, CO 80527 Test File: Encore Homes 508 Bannock -BD Technician: Paul Higman Project Number: Building Address: 508 Bannock Fort Collins, CO 80524 856 CFM50 (+1- 0.6 %) 3.47 ACH50 0.5553 CFM50/ft2 floor area 86.1 in2 (+/- 2.6 %) Canadian EgLA @ 10 Pa 45.2 in2 (+/- 4.1 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 63.3 ( +/- 6.5 %) Exponent (n) = 0.666 ( +/- 0.017 ) Correlation Coefficient = 0.99768 Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 44.8 CFM 0.18 ACH Winter: 76.3 CFM Summer: 42.8 CFM 0.31 ACH 0.17 ACH Paul Digitally signed by: Paul Higman DN:,CN = Paul H i g m a n'igman C= US J Date: 2014.03.17 05`:40:06-06-00- BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 3-12-14 Test File: Encore Homes 508 Bannock -BD Building Information Location Climate Information Volume 14820 Surface Area Floor Area 1542 Height 16 # of Bedrooms 2 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 3-12-14 Test File: Encore Homes 508 Bannock -BD Depressurization Test: Environmental Data Indoor Temperature (A°F) Outdoor Temperature (A°F) 65.0 39.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.2 n/a n/a -60.2 -59.1 28.9 981 956 -0.1 Ring A -55.9 -54.8 241.6 920 897 -1.5 Ring B -50.2 -49.1 217.8 874 852 0.7 Ring B -45.4 -44.3 188.2 813 793 0.3 Ring B -41.5 -40.4 170.5 774 755 1.6 Ring B -35.6 -34.5 132.0 682 665 -0.6 Ring B -30.2 -29.1 111.4 627 611 2.4 Ring B -25.5 -24.4 77.9 525 512 -3.6 Ring B -20.2 -19.1 60.2 462 450 -0.2 Ring B -1.0 n/a n/a Deviations from Standard CGSB - Test Parameters None BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 3-12-14 Test File: Encore Homes 508 Bannock -BD Comments House wrt Garage =-45.2pa