Conditioned Area: 1422 sq. ft. HouseType: Single-family detached
Conditioned Volume: 13860 cubic ft. Foundation: Conditioned crawl space
Bedrooms: 2
Mechanical Systems Features 1
Heating: Fuel -fired air distribution, Natural gas, 95.0AFUE.
Cooling: Air conditioner, Electric, 13.0 SEER.
Water Heating: Conventional, Electric, 0.95 EF, 40.0 Gal.
Duct Leakage to Outside: 22.00 CFM.
Ventilation System: Exhaust Only: 79 cfm, 24.0 watts.
Programmable Thermostat: Heating: Yes Cooling: Yes
LBurldmg Shell Features
Ceiling Flat: R-38 Exposed Floor: R-38
Vaulted Ceiling: R-30 Window Type: U.0.33,SHGC0.31
Above Grade Walls: R-19, R-15 Infiltration:
Foundation Walls: R-19.0 Rate: Htg: 856 Clg: 856 CFM50
Slab: None Method: Blower door test
Lights and Appliance Features 7
Percent Interior Lighting: 0.00 Range/Oven Fuel: Electric
Percent Exterior Lighting: 0.00 Clothes Dryer Fuel: Electric
Refrigerator (kWh/yr): 575.00 Clothes Dryer EF: 3.01
Dishwasher Energy Factor: 0.64 Ceiling Fan (cfm/Watt): 0.00
The Home Energy Rating Standard Disclosure for this home is available from the rating provider.
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
O 1985-2012Architectural Energy Corporation, Boulder, Colorado.
Registry ID:
Rating Number:
Certified Energy Rater: Paul Higman
Rating Date: 3-12-14
Rating Ordered For: Encore Homes
Estimated Annual Energy Cost
Confirmed Rating
Use
MMBtu
Cost
Percent
Heating
44.0
$283
19%
Cooling
1.8
$52
3%
Hot Water
11.4
$335
22%
Lights/Appliances
20.2
$591
39%
Photovoltaics
-0.0
$-0
-0%
Service Charges
$240
16%
Total
$1502
100%
This home meets or exceeds the minimum
criteria for all of the following:
2006 International Energy Conservation Code
2009 International Energy Conservation Code
City of Fort Collins Green CodeAdmendments'
Compliance with criteria for this program is
determined by the rater.
Digitally signed
Masco Home Services Pain by- Paul Higman
2339 Beville Rd DN: CN = Paul
Daytona Beach, FL.32119 Higman C = US
3860-304-2200 H I g m a n Date: 2014.03.
17%05:45:42 -
06'00'
Fort Collins
/"'�..
Planning, Development & Transportation Services
Community Development & Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
❑Stock Plan Permit — Projected Worst -Case Rating
❑Lot -specific Permit - Projected Rating
17 Completed Home — Confirmed Rating
Data Required for All SPA Ratings
Builder: Encore Homes
Energy rater:
Paul Higman
Builder Model:
Address:
Address:
508 Bannock
Rating Firm:
Thermal Concepts
Date: 3-12-14
Duct Location Inputs
Location
Su ply
Return
% Area
R-Value
% Area
R-Value
All within conditioned space
100
0
100
0
Utility Rates
Energy Source
Service charge
Rate
Electricity
5 $/month
0.10 $/kWh
Natural gas
15 $/month
0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit — Projected Worst -Case Rating
"Worst -case" configuration:
Foundation
Options included
Orientation of front elevation
HAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot -Specific Permit — Projected Rating
Btlachach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City -approved rates on lot -specific permit application date.)
Attach Home Energy Rating Certificate
Updated 11/09/2012
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
Date: March 17, 2014
Rating No.:
Building Name: 508 Bannock
Rating Org.:
Thermal Concepts
Owners Name: Encore Homes
Phone No.:
970-223-7090
Property: 508 Bannock
Raters Name:
Paul Higman
Address: Fort Collins, CO 80524
Rater's No.:
6784592
Builders Name: Encore Homes
Weather Site: Ft Collins, CO
Rating Type:
Confirmed Rating
File Name: Encore Homes 508 Bannock -Avery-final.blg
Rating Date:
3-12-14
Annual Energy Cost ($)
FC 2012
As Designed
Heating:
341
327
Cooling:
72
66
Water Heating:
335
335
SubTotal - Used to Determine Compliance:
748
729
Lights &Appliances:
595
601
Photovoltaics:
-0
-0
Service Charge:
240
240
Total:
1583
1570 '
Window U-Factor Check (Section 402.5)
Window U-Factor (Design must be equal or lower): 0.400 0.330
Home Infiltration (Section 402.42): PASSES
Duct Leakage (Section 403.2.2): PASSES
This home MEETS the annual energy cost requirements and verifications of Section 405 of the 2009 International Energy
Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 2.6%.
Name: Paul Higman
Organization: Thermal Concepts
Signature:
Date: March 17, 2014
Design energy cost is based on the following systems: 1 "U 1 rllgman
Heating: Fuel -fired air distribution, 64.0 kBtuh, 95.0AFUE. DN::CN = Paul Higman C =
Cooling:Air conditioner, 24.0 kBtuh, 13.0 SEER. I Y Y1 Y1 , 115
Water Heating: Conventional, Elec, 0.95 EF. 1 1 1 1 1 Date: 2014.03.17 05:45:12
Window -to -Floor Area Ratio: 0.12
Blower door test: Htg:856 Clg: 856 CFM50 '06'00'
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been
changed
prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies
are set
REM/Rate - Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.
FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT
508 Bannock Page 2
equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and
software
updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum
standards.
REM/Rate -Residential Energy Analysis and Rating Software v12.97
This information does not constitute any warranty of energy cost or savings.
01985-2012 Architectural Energy Corporation, Boulder, Colorado.