HomeMy WebLinkAbout2521 SUNBURY LN - DISCLOSURES - 4/24/2014Date of Test: 4-24-14 Customer: Journey Homes 7721 W 20th St L-200 Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: Infiltration Estimates BUILDING LEAKAGE TEST GS Services 2000 South College Ave suite 308 Fort Collins, CO 80525 Test File: Journey Homes 2521 Sunbury BD Technician: Paul Higman Project Number: Building Address: 2524 Sunbury Lane Fort Collins, CO 80525 943 CFM50 (+/- 0.5 %) 3.45 ACH50 0.5328 CFM50/ft2 floor area 75.9 in2 (+/- 2.2 %) Canadian EgLA @ 10 Pa 35.1 in2 (+/- 3.5 %) LBL ELA @ 4 Pa Flow Coefficient (C) = 40.6 ( +/- 5.6 %) Exponent (n) = 0.804 ( +/- 0.015 ) Correlation Coefficient = 0.99882 Test Standard: CGSB Test Mode: Depressurization 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: 34.8 CFM 0.13 ACH Winter: 59.3 CFM Summer: 33.3 CFM 0.22 ACH 0.12 ACH Digitally signed by: Paul I?au�Higman DI: CN = Paul H ig manHignan C = US Die: 2014.04.25 06: `3 21-06'00' ,. GSSer�tes BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 4-24-14 Test File: Journey Homes 2521 Sunbury BD Building Information Volume 16388 Surface Area Floor Area 1770 Height 16 # of Bedrooms 3 # of Occupants Year of Construction 2014 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Location Climate Information Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6020 Cooling Degree Days 287 Design Winter Wind Speed 9.0 mph Design Summer Wind Speed 7.0 mph Design Winter Temp Diff 69 deg F Design Summer Temp Diff 16 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 GS Se t' S BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 4-24-14 Test File: Journey Homes 2521 Sunbury BD Depressurization Test: Environmental Data Indoor Temperature (A°F) I Outdoor Temperature (A°F) 67.0 65.0 Data Points - Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.1 n/a n/a -60.2 -58.2 33.5 1054 1052 -1.2 Ring A -55.6 -53.6 30.5 1006 1004 0.8 Ring A -50.2 -48.2 241.1 919 917 0.3 Ring B -45.9 -43.9 202.5 843 841 -0.9 Ring B -40.5 -38.5 170.9 775 774 1.3 Ring B -35.4 -33.4 137.2 695 694 1.9 Ring B -30.6 -28.6 103.7 605 604 0.5 Ring B -25.1 -23.1 69.4 496 495 -2.1 Ring B -20.3 -18.3 47.7 412 411 -1.9 Ring B -2.0 n/a n/a Deviations from Standard CGSB - Test Parameters None .: =�� . GS S2 �,�5 gUILDING LEAKAGE TEST Page 4 of 4 Date of Test:4-24-14 Test File: Journey Homes 2521 Sunbury BD Comments House wrt Garage=-47.2pa City of Fort Collins Planning, Development & Transportation Services �'"�"�,,,,,,`��, Community Development & Neighborhood Services Simulated Performance Alfernative (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit—Projected Worst-Case Rating Builder Model: �Lot-specific Permit- Projected Rating Address: ❑� Completed Home—Confirmed Rating Ada�ess: 2521 Sunbury Lane Data Required for All SPA Ratings Builder: Journey Homes Rating Firm: GS S@NIC@S Energy rater: PaUI HIgCT1811 Date: 4-24-14 Duct Location In uts Location Su I Return % Area R-Value °/a Area R-Value All within conditioned space 100 0 100 0 Utili Rates Ener Source Service char e Rate Electricity 5 $/month 0.10 $/kWh Natural gas �5 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst-Case Rating "Worst-case"configuration: Foundation type(s) Options included Orientation of front elevation eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit— Projected Rating �ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home —Confirmed Rating ❑� Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.) �Attach Home Energy Rating Certificate Updated 11/09/2012