HomeMy WebLinkAbout2263 MARSHFIELD LN - DISCLOSURES - 4/25/2014"A 9servir-F-,s
Date of Test: 4/25/2014
Customer: Journey Homes
7251 W 20th Street
L-200
Greeley, CO 80634
Phone: 970-449-1612
Test Results
1. Airflow at 50 Pascals:
(50 Pa = 0.2 w.c.)
2. Leakage Area:
3. Building Leakage Curve:
BUILDING LEAKAGE TEST
GS Services
2000 South College Ave
suite 308
Fort Collins, CO 80525
Test File: Journey Homes 2263 Marshfield -BD
Technician: Paul Higman
Project Number:
Building Address: 2263 Marshfield
Fort Collins, CO 80524
1500 CFM50 (+/- 2.0 %)
3.61 ACH50
82.5 in2 LBL ELA @ 4 Pa
Flow Coefficient (C) = 150.0 (+/- 14.2 %)
Exponent (n) = 0.589 ( +/- 0.039 )
Correlation Coefficient = 0.99721
4. Test Settings: Test Standard: RESNET Multi -Point Test
Test Mode: Depressurization
5. Accuracy Level Standard Level of Accuracy Test
Infiltration Estimates
1. Estimated Average Annual Infiltration Rate: 84.8 CFM
0.20 ACH
2. Estimated Design Infiltration Rate: Winter: 136.7 CFM Summer: 90.7 CFM
0.33 ACH 0.22 ACH
Cost Estimates
1. Estimated Cost of Air Leakage for Heating:
2. Estimated Cost of Air Leakage for Cooling:
Pau I Digitally signed by:
Pauj,Higman
i DNS: CN = Paul
Hig�"�"�a " ig anC=US
:Jnfi, Dab 2014.04.28
5 08V.36:40-06-00'
BUILDING LEAKAGE TEST Page 2 of 4
Date of Test: 4/25/2014 Test File: Journey Homes 2263 Marshfield -BD
Building Information
Volume
24929
Surface Area
Floor Area
2695
Height
18
# of Bedrooms
3
# of Occupants
Year of Construction
2014
Wind Shield
M
Heating and Cooling Cost and Efficiency Information
Heating Fuel Gas
Heating Fuel Cost
Heating Efficiency %
Cooling Fuel Cost
Cooling SEER
Location Climate Information
Ventilation Weather Factor
0.87
Energy Climate Factor
17.00
Heating Degree Days
6128
Cooling Degree Days
297
Design Winter Wind Speed
7.3 mph
Design Summer Wind Speed
9.4 mph
Design Winter Temp Diff
73 deg F
Design Summer Temp Diff
15 deg F
Equipment Information
Type
Manufacturer
Model
Serial Number
Custom Calibration Date
Fan
Energy Conservatory
Model 3 (110V)
Default
Micromanometer
Energy Conservatory
DG700
"= =a�'�
GS�eY�1C�5 BUILDING LEAKAGE TEST Page 3 of 4
Date of Test: 4/25/2014 Test File: Journey Homes 2263 Marshfield-BD
Depressurization Test:
Environmental Data
Indoor Temperature (A°F) Outdoor Temperature(A°F) Altitude(ft)
68.0 70.0 4980.0
Data Points-Data Entered Manually
Nominal BaselineAdjusted Fan Nominal Adjusted
Building Pressure Building Pressure Pressure Flow Flow Fan
(Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration
-2.1 n/a n/a
-60.2 -58.2 83.3 1642 1673 2.0 Ring A
-55.1 -53.1 73.0 1540 1569 1.0 Ring A
-50.2 -48.2 64.1 1445 1472 0.3 Ring A
-45.5 -43.5 55.0 1341 1366 -1.1 Ring A
-40.0 -38.0 47.0 1242 1265 -0.8 Ring A
-35.4 -33.4 39.3 1138 1159 -1.9 Ring A
-30.4 -28.3 32.1 1032 1051 -2.1 Ring A
-25.2 -23.1 248.5 933 951 -0.3 Ring B
-20.2 -18.1 198.7 835 851 3.0 Ring B
-2.0 n/a n/a
Time Averaging Period: 10
Deviations from Standard RESNET Multi-Point Test-Test Parameters
None
G$��2 �C��S BUILDING LEAKAGE TEST Page 4 of 4
Date of Test:4/25/2014 Test File: Journey Homes 2263 Marshfield-BD
Comments
House WRT Garage=-47.9pa
Cityof Planning, Development & Transportation Services
Fort Collins
/""\,,,,.f, Community Development& Neighborhood Services
Simulated Performance Alternative (SPA) Cover Sheet
Submittal and Rating Type
�Stock Plan Permit—Projected Worst-Case Rating Builder Model:
�Lot-specific Permit-Projected Rating Address:
❑� Completed Home—Confirmed Rating Ada�ess: 2263 Marshfield
Data Required for All SPA Ratings
Builder: �ourney Homes Rating Firm: GS S@CVIC@S
Energy rater: PaUI H19�71811 �ate: 4-25-14
Duct Location In uts
Location Su I Return
% Area R-Value %Area R-Value
All within conditioned space 100 0 100 0
Utilit Rates
Ener Source Service char e Rate
Electricity 5 $/month 0.10 $/kWh
Natural gas �5 $/month 0.60 $/therm
Spaces considered outside the thermal boundary:
Additional Information for Stock Plan Permit— Projected Worst-Case Rating
"Worst-case"configuration:
Foundation type(s)
Options included
Orientation of front elevation
BAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
Attach REM/Rate Energy Code Inspection Checklist
Additional Information for Lot-Specific Permit— Projected Rating
ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
ttach REM/Rate Energy Code Inspection Checklist
Additional Information for Completed Home — Confirmed Rating
❑� Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report
(Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.)
�Attach Home Energy Rating Certificate
Updated 11/09/2012