Loading...
HomeMy WebLinkAbout2251 MARSHFIELD LN - DISCLOSURES - 4/24/2014 (6)BUILDING LEAKAGE TEST l v� o` xoeryices Date of Test: 4-24-14 Customer: Journey Homes 7251 W. 20th Street L-200 Greeley, CO 80634 Test Results 1. Airflow at 50 Pascals: (50 Pa = 0.2 w.c.) 2. Leakage Areas: 3. Building Leakage Curve: 4. Test Settings: Infiltration Estimates GS Services 2000 S. College Ave suite 308 Fort Collins. CO 80525 Test File: Journey Homes 2251 Marshfield Lane BD Technician: Paul Higman Project Number: Building Address: 2251 Marshfield Lane Fort Collins, CO 80524 1016CFM50(+/-0.5%) 2.44 ACH50 0.3769 CFM50/ft2 floor area 76.9 in2 (+/- 2.2 %) Canadian EgLA @ 10 Pa 34.4in2(+/-3.5%)LBLELA@4Pa Flow Coefficient (C) = 37.7 ( +/- 5.6 %) Exponent (n) = 0.842 ( +/- 0.015 ) Correlation Coefficient = 0.99895 Test Standard: CGSB Test Mode: Depressurization 1. Estimated Average Annual Infiltration Rate: 27.6 CFM 0.07 ACH 2. Estimated Design Infiltration Rate: Winter: 43.4 CFM Summer: 25.6 CFM 0.10 ACH 0.06 ACH Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: Digitally signed by: Paul P,a kigman DNS: CN = Paul HigmanHg�an C= US pa e: 2014.04.25 08: 1.24-06'00' �= '•�� . GS�e G,�S gUILDING LEAKAGE TEST Page 2 of 4 Date of Test:4-24-14 Test File: Journey Homes 2251 Marshfield Lane BD Building Information location Climate Information Volume 24929 Ventilation Weather Factor 0.87 Surface Area Energy Climate Factor 17.00 FloorArea 2695 Heating Degree Days 6020 Height 8 Cooling Degree Days 287 #of Bedrooms 3 Design Winter Wind Speed 9.0 mph #of Occupants Design Summer Wind Speed 7.0 mph Year of Construction 2014 Design Winter Temp Diff 69 deg F Wind Shield M Design Summer Temp Diff 16 deg F Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency% Cooling Fuel Cost Cooling SEER Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 GS�S��1-C�S BUILDING LEAKAGE TEST Page 3 of 4 Date of Test:4-24-14 Test File: Journey Homes 2251 Marshfield Lane BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) 67.0 71.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -1.2 n/a n/a -60.0 -59.0 41.7 1172 1176 0.7 Ring A -55.1 -54.1 35.8 1088 1092 0.5 Ring A -50.4 -49.4 30.0 998 1002 -0.5 Ring A -45.1 -44.1 235.3 908. 911 -0.4 Ring B -40.0 -39.0 189.2 815 818 -0.8 Ring B -35.4 -34.4 152.3 732 735 -1.0 Ring B -30.4 -29.4 114.3 635 637 -2.0 Ring B -25.6 -24.7 88.7 560 562 0.4 Ring B -20.4 -19.4 64.2 477 479 4.4 Ring B -0.7 n/a n/a Deviations from Standard CGSB-Test Parameters None d' *�1� GS��S BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 4-24-14 Test File: Journey Homes 2251 Marshfield Lane BD Comments House wrt Garage=-46.2pa Cityof Planning, Development & Transportation Services Fort Collins /"''�.`�•.� Community Development& Neighborhood Services Simulated Performance Alternafive (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit—Projected Worst-Case Rating Builder Model: �Lot-specific Permit- Projected Rating Address: �Completed Home—Confirmed Rating Ada�ess: 2251 Marshfield Lane Data Required for All SPA Ratings euilder: �ourney Homes Rating Firm: GS S@NIC@S Energy rater: PaUI HIg�718n Date: 4-24-14 Duct Location In uts Location Su I Return % Area R-Value %Area R-Value All within conditioned space 100 0 100 0 Utilit Rates Ener Source Service char e Rate Electricity 5 $/month 0.10 $/kWh Natural gas �5 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst-Case Rating "Worst-case"configuration: Foundation type(s) Options included Orientation of front elevation eAttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit— Projected Rating �ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home— Confirmed Rating ❑� Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.) �Attach Home Energy Rating Certificate Updated 11/09/2012