Loading...
HomeMy WebLinkAbout420 E ELIZABETH ST - SPECIAL INSPECTIONS - 5/6/2010D M FERRIN 4336 E County Road 48 Fort Collins Colorado 80524 970 493 9394 Date 5 6 10 Site Solutions Attn Brian Stephenson 1025 N Highway 287 — Suite #3 Fort Collins CO 80524 Site Address 420 E Elizabeth Ft Collins CO 80524 P E #11585 B1003044 Emergency escal: e and rescue window is required for every basement and sleeping room The opening moat have a min dear opening of 5 7 sq ft. 24 min height and V min wft Sight of 44 max above floor Escape window well shall have a horizontal min opening of 9 4 R 8 a min pmpc4on and width of 36' Well depths greater than 44 must be equipped with a permanent ladder or stairs Per Section 313 SMOKE ALARMS Are REQUIRED throughout Dwelling unit The above site was personally inspected on May 6 2010 The site indicates the existing windows that are to be removed and replaced with an approved egress window are located on the front southeast corner and the west middle window of the house The existing windows have a wooden header covered by stucco type material The new egress window will require no disturbance to this existing header and is therefore approved for replacement The foundation wall is concrete but creates no problems structurally if the window opening is enlarged as the header is adequate to carry the resulting loads without further reinforcement Sincerely David Femn PE #11585 Sto* low requires a Carbon Monoxide Alarm wdhin 15 feet cf na h bedroom r,n d M POP OPSTE�� "�i'�j *r-411585ar v,�%S--7- :0 eL4%J;AA p lop QO OF Co h n IF B1003044 Pervu.�t m pate LVL t�aL�Zec1 Pia V4 R.evLew pate .Z.,ovzvva F)Mew Proposed Vtse pate C,Ooscr CACIOV Vol L'ce =, end Md ress r