HomeMy WebLinkAbout909 CENTRE AVE - SPECIAL INSPECTIONS - 9/13/2005Sep 13 05 07:43a PPRBD 7193272988 p.2 THOMAS EVANCICH III ELEVATOR INSPECTIONS N.A.E.S.A. Q.E.I. # C-1696 1935 WINSTON RD. COLORADO SPRINGS, CO.80909 719-63 4-1016---719-650-8700 Sept.13-2005 To: Ft. Collins Bldg. Dept. 281 College Ave. Ft. Collins CO 80522-0580 Attn: Mike Gebo Re: Acceptance inspection Sept 12-2005 for the Schindler passenger -hydro Elevator # 6402—Center Car # 1 located at: Winslow Independent Living 909 Centre Ave. Ft. Collins CO 80526 Inspection performed under guidelines of ASME A17.1-2004 / NFPA 70 (NEC) The following items are non -compliant: 1) Working programmed phone A17.1 Rule 2.27.1.1 2) Fire seal hoistway penetrations A17.1 Rule 2.1.1.1.1 3) Sump requirements in pit A17.1 Rule 2.2.2.4 (Not required per Bldg. Dept.) Phase I & II Fire Service key operation tested & approved. (Smoke & Heat test by Fire Dept.) Thank You Thomas Evancich III Sep 13 05 07:43a PPRHD 7193272988 p.3 THOMAS EVANCICH III ELEVATOR INSPECTIONS N.A.E.S.A. Q.E.I. # C-1696 1935 WINSTON RD. COLORADO SPRINGS, CO.80909 719-634-1016---719-650-8700 Sept.13-2005 To: Ft. Collins Bldg. Dept. 281 College Ave. Ft. Collins CO 80522-0580 Attn: Mike Gebo 13,9,0110 9�i3�a5 Re: Acceptance inspection Sept 12-2005 for the Schindler passenger -hydro Elevator # 6404—South Car # 2 located at: Winslow Independent Living 909 Centre Ave. Ft. Collins CO 80526 Inspection performed under guidelines of A SMF A 17 1-2004 / NFPA 70 (NEC) The following items are non -compliant: 1) Fire seal hoistway penetrations A 17.1 Rule 2.1.1.1.1 2) Sump requirements in pit A 17.1 Rule 2.2.2.4 (Not required per Bldg. Inept.) Phase I & II Fire Service key operation tested & approved. (Smoke & Heat test by Fire Dept.) Thank You k� Thomas Evancich III Sep 13 05 07:43a PPRHD 7193272988 p.5 ELEVATOR CERTIFICATE OF INSPECTION Date: Sept 12-2005ylo 3i/D Name of Building: Winslow Independent Living — South Car # 2 Address: 909 Centre Ave Ft. Collins CO 80526 Elevator Manufacturer: Schindler Elevator I.D. HGB 6404 Rated Load: 2500lbs. This elevator was inspected on the above date. A report on the results thereof is on file with the authority having jurisdiction. Inspector:-14 N.A.E.S.A. Certification # C1696 Thomas Evancich III Sep 13 05 07:44a PPRBD 7193272988 p.6 ELEVATOR CERTIFICATE OF INSPECTION Date: Sent 12-2005 le 111-151,s Name of Building: Winslow Independent Living North Car # 3 Address: 909 Centre Ave Ft. Collins CO 80526 Elevator Manufacturer: Schindler Elevator I.D. HGB 6403 Rated Load: 2500lbs. This elevator was inspected on the above date. A report on the results thereof is on file with the authority having jurisdiction. i N.A.E.S.A. Certification # C1696 Thomas Evancich III Sep 13 05 07:43a PPRBD 7193272998 p.4 ELEVATOR CERTIFICATE OF INSPECTION Date: Sept 12-2005 Name of Building: Winslow Independent Living —Center Car # 1 Address: 909 Centre Ave Ft. Collins CO 80526 Elevator Manufacturer: Schindler Elevator I.D. HGB 6402 Rated Load: 2500lbs. � //,, 1/1 �, - This elevator was inspected on the above date. A report on the results thereof is on file with the authority having jurisdiction. N.A.E.S.A. Certification # C1696 Thomas Evancich III