Loading...
HomeMy WebLinkAbout626 REMINGTON ST - CORRESPONDENCE - 4/8/2005 (2)C6. No Text The A.J. SHIRK ROOFING COMPANY contract in #2 states "All work to be done in accordance with local codes and manufacture's specifications.....". These are some the areas where the roof fails to meet the manufactures specifications as set forth in the Cedar Shake and Shingle Bureau - New Roof Construction Manual (herein referred to as "the manual"). 1. The shingles used, "FIVE X" (16"), should have a maximum weather exposure of 5 inches as specified in the manual page 1, Table 2 - Shingle Exposure, and on back of the label on each bundle of shingles. 2. The spacing between shingles described on the back of the label and in the manual page 5, "Certi-label Shingle Application" #3 `Spacing between adjacent shingles (joints) should be a minimum of 'Wand a maximum of 3/8"'. 3. Fasteners should be 3d x 1 %* box nails, larger nails cause cracking of shingles. ROOF 626 REMINGTON Page 1 of 2 4.The width as referred to in the manual page 5, "Certi-label Shingle Application" #6 - "Flat grain shingles wider than 8" should be split in two before nailing. Knots and similar defects should be treated as the edge of the shingle and the joint in the course above placed 1'/2" from the edge of the defect." Our shingles are labeled 100% edge grain. ROOF 626 REMINGTON Page 2 of 2