HomeMy WebLinkAbout601 ENDICOTT ST - SPECIAL INSPECTIONS - 6/16/2009Robinson Engineering, Inc (970) 2174960 105 South Meldrum Street #4 PO Box 2459, Fort Collins, Colorado 80522 June 16, 2009 Fort Collins Building Department and Steve Josephs Craftsmen Builders 319 East Magnolia Street Fort Collins, CO 80523 Dear Sirs, . El UP He � 0 " , I ME MIDI RE: Basement Window Headers, Manvel House, 601 Endicott Street, Fort Collins, CO 80524. I met with Steve Josephs of Craftsman Builders on site to evaluate the feasibility of widening several windows in the basement of the home at 601 Endicott in February. Following that visit, I recommended that the windows could be widened as discussed and suggested that the headers over the windows could be a single 2x8. Since that time, Craftsmen Builders have widened the windows. During the construction process, a 2x8 was added to the rim joist above the modified windows, effectively doubling the rim joist. In all cases, the joists were running parallel to the window openings, thus the primary load supported by the headers was roof load and well within the capacity of the doubled rim joists. As a structural engineer, it is my opinion that the doubled rim joist headers over the widened windows are both adequate and appropriate to support the site loads for this home. Please call if there are further questions. C3 u V / Sincerely,UJ ��p ,..•• 0 Geoff Robinson. PE Civil / Structural Engineer The inspection and comments in this letter are specific items as presented and in no way imply a certification or complete inspection of the structure, its systems or site work. No liability is assumed for future loss of value, marketability or any other loss claims. Craftsmen 6-16-09 601 Endicott.odt Project: 9-009