HomeMy WebLinkAbout6944 ROSEMONT CT - DISCLOSURES - 5/3/2005Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 05/03/0, (970)377-1056 CUSTOMER: KB Homes 6944 Rosemont Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 40 F Volume = 25500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 54 146 2070 1.1 Ring A 49 129 1947 —1.5 Ring A 40 113 1824 —0.6 Ring A 32 99 1708 1.1 Ring A 25 82 1556 0.8 Ring A 20 67 1408 —1.0 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9965 C = 473.47 n = 0.367 Results: Air Flow @ 50 Pascals : = 1991 CFM50 +/— 0.7% 4.69 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 223.31 Square Inches +/— 3.5% Equivalent Leakage Area (CANADA) = 323.86 Square Inches +/— 2.1% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 147 CFM = 73.4 CFM/OCCUPANT = 0.35 AIR CHANGES PER HOUR JoAa rv� S)6wa��