Loading...
HomeMy WebLinkAbout4315 JOHN F KENNEDY PKWY - CORRESPONDENCE - 3/19/1997HEIL COMPANY Fax : 719-636-9226 Mar 27 197 13:20 Gasfite March 19, 1997 Mr. Jim Heil. Gastite Agent Heil Company P.O. Box 1520 Silvcr/horac, CO 80498 Rc: Old Timc Sheetmetal letter dated. 217197 Tileflex Corporation 603 Hendee SKeet P.O. Box 90054 Springfield, MA 01139. Telephorte (413) 739-5631 Facsimile (413) 739-7325 Dear Jim, please use this letter as necessary to respond to any questions that arise conctming the letter written by Dan Oraham, of Old Time Sheetmend. regarding a Gasthe/Goodman installation at JFK parkway. A 2 psi gas piping system utilizes a "pounds to inches" Maxitrol regulator to adjust the inlet pressure (1 to 2 lbs.) to a factory set outlet pressure of 8"w.c. for narmal gas installations. Assuming the system is installed per Gastitc and Maxitrol specifications, there would he 8" w.c. at the inlet of the Goodman appliance under a no -flow, static condition. The 8"w.c. Gastitc line sizing table allows for a maximum 3" we, drop, between the outlet of the regulator and the appliance. Therefore, under full flow condition the pressure in front of each appliance would he equal to or greater than 5"w.c., depending on the langdo, and of course no greater than 8" w.e.. If The contractor is not experiencing these ranges of performance, I would like to explore the possibility of an installation error or d defective regulator. This range of 5" to 8" w.c. is acceptable per the AGAIANSI I.CI specification for this type of installation, a$ well as the Goodman Manufacturing Co. if you should have further questions on this, you can contact Richard Folks, the Goodman Technical Representative, at (713) 861 - 2500. As for the accusation that the regulator is a "non lock -down" regulator, this is incorrect. The Maxitro1325 Series regulators deliver dead cnd lock up to the 65 psi emergency exposure limit. This information can be acquired from Maxiuol's product bulletin MS2055 3196, or by speaking with Maxitroi's Technical Representative, Richard Mathison at (810) 356.1400. A 2psi Gastite installation installed in accordance with the Gastite Design and Installation Guide is the safest gas piping .system available. This is due to the stainless steel product integrity and the reduced number of fittings in any installation. A "pounds to inches" regulator even improves safety as it can function as secondary protection to appliances in the very unlikely event the meter service regulator fails. 'l'hc installation of Gastite flexible gas piping system per our installation guidelines is to code, as our product is approved in the Uniform Mechanical Code 19% as well as every model code across the United States and Canada, less UPC where the product is only listed. Additionally, it's use is covered by NFPA54 and ANSIIAGA LCI. We have suaxssfully completed 75.000 residential installations to date across the U.S.. Iryou should require further information. please don't heSitale to csll, Sincerely, v"rG�v��t Mark Harris Operations Manager Q MH/aw Or%0 74r cc: D. Munroe. Heil Co. It. Roberts, l'iteflex S. ftockenberry,'fiteflex A mumWr of 0 T 1 GROUP