Loading...
HomeMy WebLinkAbout6933 ROSEMONT CT - DISCLOSURES - 3/31/2005 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 03/31/05 (970)377-1056 STOMER: Kaufman and Broad 6933 Rosemont Ct. Fort Collins ,CO CLDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 40 F Volume = 25400 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 JSE TEST : Depressurized Fan Model = 3 Performed By SARA :a Points: House Pressure Fan Pressure CFM %Error Fan Configuration 56 111 1808 1.6 Ring A 50 98 1700 —0.7 Ring A 39 79 1528 —2.8 Ring A 30 70 1439 0.3 Ring A 24 62 1355 1.9 Ring A 20 52 1242 —0.5 Ring A Correlation Coefficient Flow Coefficient Exponent r = •9922 C = 444.88 n = 0.344 ;ults : Air Flow @ 50 Pascals : 1711 CFM50 +/— 1.0% 4.04 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 203.30 Square Inches +/— 4.9% Equivalent Leakage Area (CANADA) = 288.74 Square Inches +/— 3.0% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 126 CFM = 63.1 CFM/OCCUPANT = 0.30 AIR CHANGES PER HOUR