HomeMy WebLinkAbout6908 ROSEMONT CT - DISCLOSURES - 2/1/2005 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 02/01/05 (970)377-1056 CUSTOMER: Kaufman and Broad 6908 Rosemont Ct Fort Collins ,CO Ou1LUINU UU1V1 ITIUN6: Interior Temp = 68 F Exterior Temp = 40 F Volume = 26000 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 53 125 1917 0.2 Ring A 47 117 1855 0.8 Ring A 42 103 1742 —2.0 Ring A 34 94 1665 0.3 Ring A 30 88 1612 1.0 Ring A 25 76 1499 —0.5 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9928 C = 539.96 n = 0.319 Results: Air Flow @ 50 Pascals 1878 CFM50 +/— 0.7% 4.33 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 238.08 Square Inches +/— 4.4% Equivalent Leakage Area (CANADA) = 330.22 Square Inches +/— 2.7% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 138 CFM = 69.2 CFM/OCCUPANT = 0.32 AIR CHANGES PER HOUR