Loading...
HomeMy WebLinkAbout6315 CLYMER CIR - DISCLOSURES - 1/29/2005Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 01/29/05 (970)377-1056 CUSTOMER: US Homes /�I�, 6315 Clymer W Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 50 F Volume = 35500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Data Points: Depressurized Fan Model = 3 Performed By SARA House Pressure Fan Pressure CFM %Error Fan Configuration 48 180 2319 1.1 Ring A 42 167 2235 -0.3 Ring A 33 154 2147 -0.3 Ring A 25 139 2041 -0.8 Ring A 19 125 1936 -1.5 Ring A 12 114 1850 1.6 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9916 C = 1202.12 n = 0.167 Results: Air Flow @ 50 Pascals : = 2309 CFM50 +/- 0.8% 3.90 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 429.46 Square Inches +/- Equivalent Leakage Area (CANADA) = 518.35 Square Inches +/- Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 170 CFM = 85.1 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR m �. 2.2% 1.3%