HomeMy WebLinkAbout4226 WESTBROOKE DR - DISCLOSURES - 12/9/20049 December 2004 TO: Whom it may concern FROM: Jim Evenson, ENEREGY SCORE rater, phone (970) 484-3531, fax (970) 490-2925, email: evenson@frii.com RE: Final Inspection, Energy Code compliance, Lot 38 Westbrooke; a.k.a. 4226 Westbrooke, Fort Collins, CO 80526 This home was rated from Pitner Construction's modified Ouray stock plan (an Ouray II) with rater issuing memo stating it would comply on 18 June 2004. The expanded plan used the same specifications that builder had used in other homes in the subdivision, but the geometry of the changed plan (more volume per heated floor area) caused it not to comply with code as submitted, using the default "from plans" infiltration rate. Test runs completed at that time determined the property would comply with code using those specifications if a blower door test, completed at the end of construction, proved a lower infiltration rate within the range this builder had achieved on other homes built in the subdivision. So the builder elected to have the blower door done at completion and use the specifications submitted. The home is west facing, 3-car garage left, with one of the bays of the garage in tandem. A site visit was completed 6 December, near the end of construction to complete the blower door test. Despite not being totally complete (carpets were being installed, plumbing fixtures were being set) which would have probably tightened the home further, the home tested with an infiltration rate at .22 air changes per hour, far less than the .45 air changes per hour the City has raters use as a default infiltration rate on from plans ratings. Subject has the 92.1% efficient closed combustion Heil furnace used as a spec for the subdivision; and a 50 gallon Bradford White water heater, model MI5036FBN4 which has a 54% efficiency instead of the 56% water heat specification. Rater checked for Low-E windows which were in the basement too. Rater returned on this date to complete the other final inspection items other than the flower door test finding them completed. Using the actual air infiltration rate, the rating was rerun. As is rating came out at G-84. The minimum required to pass the Energy Code requirement of G-83 for a home this size. The home is substantially built to the plans and specifications and meets the Fort Collins' Energy Code. Please do not withhold issuance of the certificate of occupancy (CO) for non-compliance with the Energy Code. r