HomeMy WebLinkAbout4226 WESTBROOKE DR - DISCLOSURES - 11/29/2004Fort Collins Residential Code 7/96
Insulation Disclosure Form
ADDRESS 4226 WESTBROOK
General Contractor PITNER HOMES
Insulation Contractor BMC WEST
Location
Materials
IThickness
Rated R-value
tion
Notes
Flat or vaulted ceilings
Blown Fiberglass
14.75
R-38
I
j
with attics above
Batt Fiberglass
I
Ceilings with enclosed
Fiberglass Batt
10
R-36
rafter cavities
Frame walls and rim joists IFiberglass Batt
to exterior Fiberglass Batt 1 3.5 1 R-13
Frame walls
Fiberglass Batt
3.5
R-13
to attics, garage
Frame Floor -cantilever IFiberglass Batt 1 10 1 R-30
Frame Floor -over garage .
Fiberglass Batt
6
R-19
or crawl space
walls lUnfaced Insulation
[Basement walls FIBERGLASS BAIT 1 3.5 1 R-11
We certify that the above -listed insulation was installed in the building at the above locations in
conformance with the current requirements of the City of Fort Collins Residential Energy Guideliness published
by the City of Fort Collins.
Certified by: Kevin Miller Phone: 1-970-356-9000
Business Firm: Bmc West Date: 11/29/2004
Address: 500 27th Street Greeley Signature: o
This disclorse form is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for he signature.
If componets vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.