Loading...
HomeMy WebLinkAbout6227 TREESTEAD CT - DISCLOSURES - 11/26/2004Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 11/26/04 (970)377-1056 JSTOMER: US Homes � , 6227 Trestead (, Fort Collins ,CO JILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 35 F Volume = 34500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 )USE TEST : Depressurized Fan Model = 3 Performed By SARA ita Points: House Pressure Fan Pressure CFM %Error Fan Configuration 51 180 2285 1.8 Ring A 47 168 2208 0.9 Ring A 41 143 2039 —2.9 Ring A 35 133 1967 —1.6 Ring A 29 121 1877 —0.4 Ring A 21 104 1742 2.0 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9809 C = 666.45 n = 0.309 ?sults: Air Flow @ 50 Pascals : 2231 CFM50 +/— 1.2% 3.88 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 289.92 Square Inches +/— 6.9% Equivalent Leakage Area (CANADA) = 398.57 Square Inches +/— 4.2% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 164 CFM = 82.2 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR