Loading...
HomeMy WebLinkAbout6227 TREESTEAD CT - SPECIAL INSPECTIONS - 4/20/2004SCOTT, COX & ASSOCIATES, INC. consulting engineers April 20, 2004 Lennar Family of Builders 2695 West Eisenhower, Suite 230 Loveland, Colorado 80537 Project No:5575-02-16-04 Gentlemen: On April 14, 2004, a representative of Scott, Cox & Associates, Inc. visually observed the perimeter drain system and damp -proofing for the new residence under construction at Lot 20, Block 16, West Chase, (6227 Treestead Court), a subdivision of Fort Collins, Colorado. We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded by gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located below the footing level and is to discharge to an interior sump pit, and an overall subdrain system. We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the damp -proofing coating adequately covered the foundation wall. As a result of our observations, it is our opinion that the drainage system and damp -proofing were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. Reviewed by: Steve Stefko Engineering Technician G:\Ofr1ice\Lenm\Leunar Family of Builders\5575-2-16-4.wpd 5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660 Serving CoWado vritn offices in • 9wlder • Longmora • Loveland Y