HomeMy WebLinkAbout6408 TILDEN ST - SPECIAL INSPECTIONS - 6/24/2004SCOTT, COX & ASSOCIATES, INC. consulting engineers zArT. June 24, 2004 Lennar Family of Builders 2695 West Eisenhower, Suite 230 Loveland, Colorado 80537 Project No:5575-02-34-05 Gentlemen: On June 17, 2004, a representative of Scott, Cox & Associates, Inc. visually observed the perimeter drain system and damp -proofing for the new residence under construction at Lot 18, Block 14, West Chase, (6408 Tilden Street), a subdivision of Fort Collins, Colorado. We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded by gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located below the footing level and is to discharge to an interior sump pit. We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the damp -proofing coating adequately covered the foundation wall. As a result of our observations, it is our opinion that the drainage system and damp -proofing were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. Reviewed by: Steve Stefko Engineering Technician GA0ffice\Lemws\Letmar Family of Builders\5575-2-34-5.wpd 5110 Granite Street, Suite D • Loveland , Colorado 80538 • (970) 663-0138 • Fax: (970) 663.1660 Serving Colorado with offices in • BWlder • Longmont • Loveland