Loading...
HomeMy WebLinkAbout608 PEYTON DR - SPECIAL INSPECTIONS - 9/21/2004September 21, 2004 DR Horton, Melody Series 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Corey Weaver Re: Exterior Perimeter Drain Observation Ridgewood Hills 3rd Filing 608 Peyton Dr. - Lot 108 Fort Collins, Colorado Terracon Project No. 20005162 Dear Mr. Weaver: Irerracon 301 North Howes - P.O. Box 503 Fort Collins, Colorado 80521.0503 (970) 484.0359 Fax: (970) 484.0454 A representative of Terracon observed the perimeter drain at the above referenced address on September 14, 2004, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement and crawl -space foundations with an impervious PVC membrane beneath the drainage system. The drainage pipe appeared to exhibit positive drainage toward the sump pit located within the basement area. We also observed 1'/2 inch washed gravel placed above and below the pipe and drainage filter fabric above the gravel. The waterproofing/ damp -proofing was also observed and in our opinion was uniformly applied to the exterior foundations. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRACON Benjamin D. Ruder, E f 61 «^- Staff Engineer_ David A. Richer, P.E. Geotechnical EngineerfDepattrnerrt lm4iiager Copies to: (2) Addressee (1) Brian Kelly — Dr Horton, Melody Series Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ North Carolina ■ Oklahoma ■Tennessee ■Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terrscon.com