Loading...
HomeMy WebLinkAbout1809 BRIGHTWATER DR - DISCLOSURES - 7/22/2004 (5)Sara. s Energy Scaring 813 Oxford LIB DATE FT. COLLINS, CO 80525 07/22/04 (970)377-1056 CUSTOMER: Kaufman and BroaQ 1809 Brightwater (ji Fart Collins ,CO BUILDING CONDITIONS: : Interior Temp = 68 F Exterior Temp = 70 F Volume = 24484 Cu. Ft. Above Grade Surface Area = Q Sq, Ft. Number of Stories = 2 lumber of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points. House Pressure Fan Pressure CFM %Error Fan Configuration 57 48 1750 1.2 Ring A 52 87 1650 -1.8 Ring A 45 80 1583 -1.4 Ring A 34 73 1513 2..9 Ring A. 26 59 1361 0.8 Ring A Zit 47 1217 -2.2 Ring A Correlation Coefficient Flow Coefficient Lament r = .9872 C = 483.00 n = 0.316 Results: Air Flow @ 50 Pascals : 1660 CFM50 +1- 1.1% 4.13 ACH50 (Air Changes Per Hour) Effective Leakage Area (LSL) = 212.06 Square Inches +f- 5.9% ",,Equivalent Leakage Area (cmu") = 243.33 Square Inches +I- 3.6% Estimated natural Infiltration (50 Pascal Flow Divided By 13.6) = 122 CFM = 61.1 CFMlOCCUPAffr = 0.30 AIR CAGES PER.HOUR