HomeMy WebLinkAbout6462 TILDEN ST - SPECIAL INSPECTIONS - 5/22/2003J�
zArT SCOTT, COX & ASSOCIATES, INC. consulting engineers
May 22, 2003
US Home Corporation
2695 West Eisenhower, Suite 230
Loveland, Colorado 80537
Project No:2250-37-55-04
Gentlemen:
On May 14, 2003, & May 16, 2003, a representative of Scott, Cox & Associates, Inc. visually
observed the perimeter drain system and damp -proofing for the new residence under construction
at Lot 24, Block 13, West Chase, (6462 Tilden Street), a subdivision of Fort Collins, Colorado.
We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded by
gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located
below the footing level and is to discharge to an interior sump pit, and an overall subdrain system.
We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the
damp -proofing coating adequately covered the foundation wall
As a result of our observations, it is our opinion that the drainage system and damp -proofing were
in general conformance with the plans and specifications. If you have any questions about our
observations or this report, feel free to contact our office.
Sincerely,
SCOTT, COX & ASSOCIATES, INC.
Reviewed by:
Steve Stefko
Engineering Technician
G:\Office\L.etters\US Home\2250-37-55-4.wpd
Approved by ��Q RE,
B. "C ICONAO�*'
35&*O
5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660
Serving Colorado with offices in • Boulder Longmont • Loveland