HomeMy WebLinkAbout420 PEYTON DR - SPECIAL INSPECTIONS - 5/28/2003May 28, 2003
Melody Homes
11031 Sheridan Blvd.
Westminster, Colorado 80020
Attn: Mr. Corey Weaver
Re: Exterior Perimeter Drain Observation
Ridgewood Hills 3rd Filing
420 Peyton Drive - Lot 190
Fort Collins, Colorado
Terracon Project No. 20005162
Gentlemen:
Irerracon
301 North Howes • P.O. Box 503
Fort Collins, Colorado 80521-0503
(970)484-0359 Fax: (970) 484-0454
A representative of Terracon observed the perimeter drain at the above referenced address on May
20, 2003, as requested. A four -inch diameter perforated PVC pipe had been placed around the
exterior perimeter of the basement and crawl -space foundations with an impervious PVC membrane
beneath the drainage system. The drainage pipe appeared to exhibit positive drainage toward the
sump pit located within the basement area. We also observed 1 %2 inch washed gravel placed above
and below the pipe and drainage filter fabric above the gravel. The waterproof dampening was also
observed and in our opinion was uniformly applied to the exterior foundations.
In our opinion the exterior perimeter drain was constructed in general accordance with the plans and
specifications for this project.
o. _
3727� z: l�
.E.
ineer
Reviewed By:
David A. Richer, P.E.
Geotechnical Engineer/Department Manager