HomeMy WebLinkAbout468 PEYTON DR - SITE PLANS - 5/26/2004PLOT PLAN FOR MP.LnDYHf1MF.,q.,
INC.
LOT 182 , BLOCK — , RIDGEWOOD HILLS P.U.D. THIRD FILING ,
CITY OF FT. COLLINS , COUNTY OF LARIMER STATE OF COLORADO.
ADDRESS 468 PEYTON DRIVE.
03.6
152.00' N47'3727"W
6'UE
04.1
-------------
LOT 182
5,200 SF.
M
I I
I
I
�
804028 s 9
,
I
I
o
I
PATIO
ax10
I
W
A
_
J
Z
i
II
14.0' 20.0'
34.OrOV
N
li
PLAN 1680 j
II
N
Z
Q
12.5'I
I
TOF= '�
TOG= �j
�4 5
Z
LOT 183
LEVEL NOTES:
I
�CR�o�
� ELEVNB i Q
5. -
BOW
a0
I
I
II
N BSMT f--------
-tI
N
+
C6
�i
ML5.
I
D)
O
-
I
II
14.0' 2 CAR
O
HUB
I
II
PORCH
GARAGE t
o oil
BOW
HSD
_
BOW
HSD
I
11 _
o
20.0'
II
*HI
I
- -
_
-
C-
HUB
+
02.4
`
p
SIGHT DISTANCE
EASEMENT
r..j
CHECK IN
�P`\s
9'UE
HSE STK BY DATE
HSE RESTK BY DATE
`9o.'s �`s6'• 01.837 00' N47'3727"W
oO Off,
01.1 R
FDN BY DATE
ISP/GRD STK BY SATE
`,D_.
PEYTON DRII/E
HBW/GRD
BY DATE
REGRD
BY DATE
REGRD
BY DATE
19w PLOT PLAN DOES NOT SHOW LOCATION OF WINDOW WELLS. FOR THEIR
LOCATION SEE STRUCTURAL ENGINEERED PLANS.
2. THIS PLOT PLAN IS BASED ON INFORMATION PROVIDED TO CARROLL do LANGE
BY THE BUILDER / DEVELOPER.
3. DIMENSIONS SHOWN AROUND THE PERIMETER OF THE STRUCTURE ARE TO THE
EXTERIOR FOUNDATION CORNERS.
4. PROVIDE AND MAINTAIN POSITIVE DRAINAGE AWAY FROM ALL FOUNDATION WALLS
PER WARRANTY REQUIREMENTS. (0.5X MINIMUM SLOPE FOR CONCRETE PANS.)
5. THIS PLOT PLAN SHOWS PROPOSED IMPROVEMENTS ONLY. FINAL CONSTRUCTION
MAY VARY.
6. FOR QUESTIONS REGARDING THE FOUNDATION DURING EXCAVATION, FORM
SETTING, AND HOUSE CONSTRUCTION REFER TO THE ENGINEERED FOUNDATION
PLANS.
7. BEFORE STAKING, THE BUILDER SHOULD VERIFY ALL HOUSE PLAN NUMBERS,
DIMENSIONS, ELEVATIONS, AND SETBACKS TO THE PLOT PLAN. IF ANY
DISCREPANCY EXISTS PLEASE CONTACT APPROPRIATE PERSON.
2' STAGGER REQUIRED
INFO STAKE: 1680 RH
2 CAR
ELEVNB
REVIE . D & APPROVED FOR STAKING
O Z
• LOCATE WATER METER PIT, LIGHT
POLE OR ANYTHING ELSE THAT MAY
WATER
EJEJUTILITY PEDESTALS
y Li
AFFECT THE DRIVEWAY LOCATION
SERVICE
OS SANITARY
R=PROPERTY LINE
H z
O
AND CALL OFFICE.
SEWER SERVICE
>�;(
BOW=BACK OF WALK
FOW=FRONT OF WALK
z
�(p
LIGHT POLE
y
E=FLOW LINE
bFIRE HYDRANT
- - —SETBACK
CMELODY.HO-MESINC.
MINIMUM SETBACKS:
_—
—EASEMENT
CALL UTILITY NOTIFICATION
CENTER OF CO
FRONT: 20
SCALE: 1"=20'
»os1 sHERIDAN BLVD.
- 1 9
1-800-922-1987
—
SIDE: 5' REAR:
DATE: 04-21-04
WESTMINSTER CO. 80020
oR 534-6700'"
REV:
PHONE. (303) 466-1831
„
&'ro;, n �,
,16'
STREET SIDE: 12
BY: JS
FAX. (303) 466-2368
fm Tw „� OF , "D •
MINIMUM
JOB 2 86
BETWEEN STRUCTURES:10'
N0: