Loading...
HomeMy WebLinkAbout6215 TREESTEAD CT - DISCLOSURES - 5/20/2004Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 05/20/04 (970)377-1056 CUSTOMER: US Homes 6215 Treestead Fort collies co BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 65 F Volume = 38500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 222 2610 1.6 Ring A 52 203 2497 0.3 Ring A 45 178 2340 -1.2 Ring A 37 152 2164 -2.3 Ring A 32 140 2078 -1.4 Ring A 24 125 1965 2.8 Ring A Correlation Coefficient- Flow.Coeff.icient Exponent r = .9851 C = 640.43 n = 0.344 Results: Air Flow @ 50 Pascals : 2456 CFM50 +/- 1.-0% 3.83 ACH5 0 ( Air Changes Per -Hour} Effective Leakage Area (LBL) = 292.36 Square Inches +/- 1,1% Equivalent Leakage Area (CANADA) = 414.95 Square Inches +/- 4,4% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 181 CFM = 90.5 CFM/OCCUPANT = 0.28 AIR CHANGES PER HOUR 3�rawa/A--