HomeMy WebLinkAbout3230 SHALLOW POND DR - SPECIAL INSPECTIONS - 11/26/2003RECE)VED DEC 1 5 M
SCOTT, COX & ASSOCIATES, INC. consulting engineers
November 26, 2003
Abbco
3324 Shallow Pond Drive
Fort Collins, Colorado 80528
Project No: 1526-25-26-08
Gentlemen:
On November 17, 2003, a representative of Scott, Cox & Associates, Inc. visually observed the
perimeter drain system and damp -proofing for the new residence under construction at Lot 6,
Block 2, Fossil Lake Ranch 1 st, (3230 Shallow Pond Drive), a subdivision of Fort Collins,
Colorado.
We observed that the completed drain system consisted of perforated corrugated flexible
polyethylene pipe surrounded by gravel, overlying a plastic liner, set outside of the foundation
walls. The drain appeared to be located below the footing level and is to discharge to an interior
sump pit.
We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the
damp -proofing coating adequately covered the foundation wall.
As a result of our observations, it is our opinion that the drainage and damp -proofing were in
general conformance with the plans and specifications. If you have any questions about our
observations or this report, feel free to contact our office.
Sincerely,
SCOTT, COX & ASSOCIATES, INC.
Reviewed by:
se Eriz
ngineering Technician
G\Office\ ettersWbbco\1526-25-26-8.wpd
5110 Granite Street, Suite D • Loveland , Colorado 80538 1970) 663.0138 • Fax: (970) 663-1660
Serving Colorado with offices in • Boulder Longmont • Loveland