Loading...
HomeMy WebLinkAbout6939 ROSEMONT CT - DISCLOSURES - 4/21/2004DATE 04/21/04 CUSTOMER: Kaufman and Broad 6939 Rosemont 0. Fort Collins ,CO Sara's Energy Scoring 813 Oxford LN FT. COLLINS, CO 80525 (970)377-1056 BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 35 F Volume = 20500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 77 1501 1.7 Ring A 52 65 1380 —1.9 Ring A 45 57 1293 —0.9 Ring A 39 50 1212 0.1 Ring A 32 41 1099 0.6 Ring A 27 34 1002 0.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9952 C = 179.33 n = 0.521 Results: Air Flow @ 50 Pascals : 1378 CFM50 +/— 0.7% 4.03 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 104.72 Square Inches +/— 6.2% Equivalent Leakage Area (CANADA) 174.90 Square Inches +/— 3.8% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 102 CFM 50.8 CFM/OCCUPANT 0.30 AIR CHANGES PER HOUR