HomeMy WebLinkAbout6303 Carmichael St - Disclosures - 03/31/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 03/31/03 (970)377-1056 CUSTOMER: Genessee 6303 Carmichael Ft. Collins CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 60 F Volume = 23500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 56 82 1587 -1.2 Ring A 43 69 1457 2.2 Ring A 36 56 1314 0.0 Ring A 28 43 1153 -1.7 Ring A 22 36 1056 0.5 Ring A 17 28 933 -0.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9969 C = 258.50 n = 0.454 Results: Air Flow @ 50 Pascals = 1525 CFM50 +/- 0.9% - 3.89 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) - 137.47 Square Inches +/- 4,0% Equivalent Leakage Area (CANADA) = 215.81 Square Inches +/- 2.4% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 112 CFM 56.2 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR