HomeMy WebLinkAbout4315 S MASON ST - SPECIAL INSPECTIONS - 1/7/2003MBICORPORATIONP.O. Box 9553, Fort Collins, CO 80325 MASTER BUILDER INTERNATIONAL Phone: (970) 482-CU Fax: (970) 48240M January 7, 2003 FIELD OBSERVATION REPORT RE: Casey's Car Care Center 4315 South Mason Fort Collins, Colorado 80526 This report is to record my observations of the foundations for the project prior to placement of concrete. In general, the reinforcing was in compliance and placed as shown on the drawings. Minor adjustments were necessary and the field personnel were so advised. The corrections were made on the spot and the pour could proceed. Signed: Raju Jairam, P.E. MBICORPORATION P.O. Box 9553, Fort Coffins, CO 80525 MASTER BUILDER INTERNATIONAL Phones (970) 482-6244 Fax: (970) 482-8336 January 30, 2003 FIELD OBSERVATION REPORT RE: Casey's Car Care Center 4315 South Mason Fort Collins, Colorado 80526 8 6 ao io yg/-' This report is to record my observations of the structure for the project prior to completion. In general, the installation was in compliance with the structural drawings. The following corrections were required and the field personnel so advised on two separate occasions. 1. Where the gists were moved, or where holes were torched through, washers shall be placed in all instances. 2. Where the man -door is framed in)the vertical member shall be continuous between horizontal members. e�i• t• ; : °�r Signed: _ ,r Raju Jairam, P.E. :., /PI!lilltll o, .