HomeMy WebLinkAbout1320 FORRESTAL DR - SPECIAL INSPECTIONS - 11/20/2002W1
SCOTT, COX & ASSOCIATES, INC. consulting engineers
November 15, 2002
US Home Corporation
2695 West Eisenhower, Suite 230
Loveland, Colorado 80537
Project No:2250-30-130-04
Gentlemen:
On November 14, 2002, a representative of Scott, Cox & Associates, Inc. visually observed the
perimeter drain system and damp -proofing for the new residence under construction at Lot 13,
Registry Ridge 1st, (1320 Forestal Drive), a subdivision of Fort Collins, Colorado.
-We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded
by gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be
located below the pier level and is to discharge to an interior sump pit.
We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the
damp -proofing coating adequately covered the foundation wall.
In addition we observed that the void forms for the foundation walls were intact.
As a result of our observations, it is our opinion that the drainage system and damp -proofing
were in general conformance with the plans and specifications. If you have any question about
our observations or this report, feel free to contact our office.
Sincerely,
SCOTT, COX & ASSOCIATES, INC.
Reviowed by:
I ;
'/ IF
r
J
Charles B. Klappr th
Lab Technician
G:\Office\Letters\US Homes\2250-30-130-4.wpd
5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660
Serving Colorado with offices in • Boulder Longmont • Loveland