HomeMy WebLinkAbout1320 FORRESTAL DR - SPECIAL INSPECTIONS - 10/31/2002/��/� SCOTT, COX & ASSOCIATES, INC. consulting engineers oOz y October 30, 2002 US Home Corporation 2695 West Eisenhower, Suite 230 Loveland, Colorado 80537 Project No:2250-30-130-02 Gentlemen: On October 28, 2002, a representative of Scott, Cox & Associates, Inc. conducted visual spot observations of the drilling and installation of the ten (10) inch diameter piers for the new residence under construction at Lot 13, Registry Ridge lst, (1320 Forestal Drive), a subdivision of Fort Collins, Colorado. The purpose of these observations was to assure that the piers were drilled correctly for the subsurface conditions encountered and to assure that the piers were constructed according to the specifications on the foundation plan by KLP, Project No.:6019. The.T. drillingsoperations encountered claystone bedrock at depths of six (6) feet to twelve (12) feet below the base of various excavation levels. The piers were drilled a total minimum length of twenty (20) to twenty four (24) feet with a minimum bedrock embedment of ten (10) feet, whichever was greater. Groundwater levels were not encountered in the borings. Casing of the borings was not required. Concrete was being placed with a concrete pumper. Reinforcing steel was being installed in each pier. As a result of our observations, it is our opinion that the construction of those piers observed were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. R vie ed by: F Charles B. Klapproth Lab Technician G:\Office\Letters\US Homes\2250-30-130-2.wpd e 7 4 R. B. `p-eadbetta.TI E. /VA1_. 5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660 Serving Colorado with offices in • Boulder Longmont • Loveland