HomeMy WebLinkAbout6126 TILDEN ST - SPECIAL INSPECTIONS - 10/23/200202/19/2003 13:15 9706631660 SCOTT COX LOVELAND PAGE 01/01
SCOTT, COX & ASSOCIATES, INC. consulting engineers
October 23, 2002
US Koine Corporation
2695 West Eisenhower, Suite 230
Loveland, Colorado 80537
Project No:2250-37-23-03
Gentlemen:
On October 18, 2002, a representative of Scott, COX & Associates, Inc. visually observed the
Perimeter drain system and damp -proofing for the new residence under construction at Lot 17, Block
3, West Chase, (6126 Tilden Street), a subdivision of Fort Collins, Colorado.
We observed that the completed drain system consisted ofperforated rigid PVC pipe surrounded by
gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located
below the footing level and is to discharge to an interior sump pit.
We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the
damp -proofing coating adequately covered the foundation wall.
In addition we observed that the void forms for the foundation walls were intact.
As a result of our observations, it is our opinion that the drainage system and damp -proofing were
in general conformance with the plans and specifications. If you have any questions about our
observations or this report, feel free to contact our office.
Sincerely,
SCOTT, COX & ASSOCIATES, INC.
Reviewed by:
eEI
ginee ' g Technician
GAOffiee\L0ttM\US Homcs\2250-37-23-3.wpd
5110 Granite Street Suite b - Loveland, Colorado 150538 • (970) 663-0138 - Fax, (970) 663-1660