Loading...
HomeMy WebLinkAbout6227 CLYMER CIR - SPECIAL INSPECTIONS - 6/27/2003D L zArT. SCOTT, COX & ASSOCIATES, INC. consulting engineers June 25, 2003 US Home Corporation 2695 West Eisenhower, Suite 230 Loveland, Colorado 80537 Project No:2250-37-66-04 Gentlemen: On June 18, 2003, a representative of Scott, Cox & Associates, Inc. visually observed the perimeter drain system and damp -proofing for the new residence under construction at Lot 15, Block 15, West Chase, (6227 Clymer Circle), a subdivision of Fort Collins, Colorado. We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded by gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located below the footing level and is to discharge to an interior sump pit, and an overall subdrain system. We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the damp -proofing coating adequately covered the foundation wall. As a result of our observations, it is our opinion that the drainage system and damp -proofing were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. Reviewed by: Steve Stefko Engineering Technician G:\Office\L.etters\US Home\2250-37-66-4.wpd 5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660 Serving Colorado with offices in • Boulder Longmont • Loveland