Loading...
HomeMy WebLinkAbout6227 CLYMER CIR - DISCLOSURES - 10/16/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 10/16/03 (970)377=1056 CUSTOMER: US Homes 6227 Clymer e-17A Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 65 F Volume = 36500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 51 35 2836 1.4 Open 46 30 2628 0.6 Open 39 22 2254 -4.0 Open 31 17 1984 -1.7 Open 25 14 1803 2.8 Open 20 10 1526 0.8 Open Correlation Coefficient Flow Coefficient Exponent r = =9939 C = 213:02 n = 0:655 Results: Air Flow @ 50 Pascals : 2759 CFM50 +j- 1.5* 4.54 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 149.68 Square Inches +/- 8.3% Equivalent Leakage Area (CANADA) = 282:50 Square Inches +/- 5,0% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 203 CFM = 101.7 CFM/OCCUPANT = 0.33 AIR CHANGES PER HOUR