Loading...
HomeMy WebLinkAbout1439 SAILCREST CT - DISCLOSURES - 12/11/2002DATE 12/11/02 CUSTOMER: Seier Construction, Attn Paul B 1439 Sailcrest Ct Ft Collins, CO 80526 567-5236 BUILDING CONDITIONS: Interior Temp = 62 F Exterior Temp = 33 F Volume = 20180 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 0 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By Evenson Entperprises Inc Data Points: House Pressure Fan Pressure CFM -.Error Fan Configuration 34 41 1103 0.3 Ring A 39 50 1217 0.9 Ring A 50 70 1437 0.9 Ring A 54 75 1487 -0.2 Ring A 43 53 1252 -2.0 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9953 C = 103.48 n = 0.670 Results: Air Flow @ 50 Pascals : 1424 CFM50 +/- 0.7% 4.23 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 74.29 Square Inches +/- 9.106 Equivalent Leakage Area (CANADA) = 142.22 Square Inches +/- 5.706 Estimated Natural Infiltration (50 Pascal Flow Divided By 14.4) = 99 CFM 0.29 AIR CHANGES PER HOUR