Loading...
HomeMy WebLinkAbout6857 RANGER DR - SPECIAL INSPECTIONS - 3/14/2003JP XAFT. SCOTT, COX & ASSOCIATES, INC. consulting engineers March 14, 2003 US Home Corporation 2695 West Eisenhower, Suite 230 Loveland, Colorado 80537 Project No:2250-39-30-01 Gentlemen: On March 12, 2003, a representative of Scott, Cox & Associates, Inc. conducted visual spot observations or the drilling and installation of the ten (10) inch diameter piers for the new residence under construction at Lot 118, Registry Ridge 1st, (6857 Ranger Drive), a subdivision of Fort Collins, Colorado. The purpose of these observations was to assure that the piers were drilled correctly for the subsurface conditions encountered and to assure that the piers were constructed according to the specifications on the foundation plan by Cobb Associates, Project No.:5022. The pier drilling operations encountered claystone bedrock at the base of various excavation levels. The piers were drilled a total minimum length of twenty (20) feet with a minimum bedrock embedment of ten (10) feet, whichever was greater. Groundwater levels were encountered in the borings at depths of twenty (20) feet below the excavation. Casing of the borings was not required. Reinforcing steel was being installed in each pier. As a result of our observations, it is our opinion that the construction of those piers observed were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. Reviewed by: J seE' gine ng Technician GAOfficeTeners\US Homes\2250-39-30-1.wpd 5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660 Serving Colorado with offices in • Boulder Longmont • Loveland