HomeMy WebLinkAbout6857 RANGER DR - SPECIAL INSPECTIONS - 3/14/2003JP
XAFT. SCOTT, COX & ASSOCIATES, INC. consulting engineers
March 14, 2003
US Home Corporation
2695 West Eisenhower, Suite 230
Loveland, Colorado 80537
Project No:2250-39-30-01
Gentlemen:
On March 12, 2003, a representative of Scott, Cox & Associates, Inc. conducted visual spot
observations or the drilling and installation of the ten (10) inch diameter piers for the new
residence under construction at Lot 118, Registry Ridge 1st, (6857 Ranger Drive), a subdivision
of Fort Collins, Colorado. The purpose of these observations was to assure that the piers were
drilled correctly for the subsurface conditions encountered and to assure that the piers were
constructed according to the specifications on the foundation plan by Cobb Associates, Project
No.:5022.
The pier drilling operations encountered claystone bedrock at the base of various excavation
levels. The piers were drilled a total minimum length of twenty (20) feet with a minimum
bedrock embedment of ten (10) feet, whichever was greater. Groundwater levels were
encountered in the borings at depths of twenty (20) feet below the excavation. Casing of the
borings was not required. Reinforcing steel was being installed in each pier.
As a result of our observations, it is our opinion that the construction of those piers observed
were in general conformance with the plans and specifications. If you have any questions about
our observations or this report, feel free to contact our office.
Sincerely,
SCOTT, COX & ASSOCIATES, INC.
Reviewed by:
J seE'
gine ng Technician
GAOfficeTeners\US Homes\2250-39-30-1.wpd
5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660
Serving Colorado with offices in • Boulder Longmont • Loveland