Loading...
HomeMy WebLinkAbout6820 AUTUMN RIDGE DR - DISCLOSURES - 8/29/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 08/29/03 (970)377-1056 CUSTOMER: Kaufman and Broad 6820 Autumn Ridge Fort Collins ,CO bU1LVIVU CONDITIONS: Interior Temp = 68 F Exterior Temp = 65 F Volume = 16200 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 57 1332 -0.8 Ring A 47 47 1211 1.0 Ring A 40 39 1104 0.5 Ring A 32 30 970 -0.4 Ring A 23 21 813 -0.1 Ring A 16 14 665 -0.5 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9994 C = 148.65 n = 0.542 Results: Air Flow @ 50 Pascals : 1239 CFM50 +/- 0.4% 4.59 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 89.36 Square Inches +/- Equivalent Leakage Area (CANADA) = 152.12 Square Inches +/- Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) = 101 CFM = 50.7 CFM/OCCUPANT = 0.38 AIR CHANGES PER HOUR 0 2.2% 1.3%