Loading...
HomeMy WebLinkAbout4315 S MASON ST - SPECIAL INSPECTIONS - 1/15/2002GENERAL STEEL ** 1075 S YUKON ST SUITE 250 LAKEWOOD CO 80226 JOB NO: 2104-199130 (0) MID -WEST STEEL BUILDING COMPANY 01/15/02 BUILDING SIZE: CS 30' X 40' X 12' JOBSITE: FORT COLLINS CO (LARIMER) Gentlemen: B02 010 48 This is to certify that the above referenced building and its component parts have been designed and fabricated by Mid -West Steel Bldg, an AISC Certified Manufacturer, at its AISC certified facility. It has been designed in accordance with the order documents, in general accordance with the ninth edition of the AISC "Manual of Steel Construction" and the 1986 Edition (with 1989 amendments) of the AISI "Cold Formed Steel Design Manual" and with good engineering practice for the following loads. All welding is per the appropriate American Welding Society (AWS) code. Governing Code for application of design loads: UBC 1997 IMP. FACTORS: WIND: 1.0 SNOW: 1.0 SEISMIC: 1.0 DEAD LOAD ... weight of metal bldg. structure only as supplied by Mid -West Steel Bldg LIVE LOAD .............. 30 PSF COLLATERAL LOAD......... 0 PSF WIND LOAD ............... 90 MPH EXP C SEISMIC ZONE............ 2A ROOF SNOW LOAD..............30 PSF This Letter of Certification applies solely to the steel building and its component parts as furnished by Mid -West Steel Bldg and specifically excludes any foundationkk�ltx' s*t' y" "eA �ontract work. Since.; y �i �. •'1i11 !e =�i�`h Presidenis'-%E-ugineering ,*a�., corporate offices: 7301 FAIRVIEW • HOUSTON, TEXAS 77041 • (713) 466-7788 • (800) 777-9378 Mailing Address: P.O. BOX 40338 • HOUSTON, TEXAS 77240-0338 • FAX (713) 466-3194