HomeMy WebLinkAbout825 E LAUREL ST - CORRESPONDENCE - 8/5/200308/05/2003 CITY OF FORT COLLINS INSPECTION DEPT. 281 NORTH COLLEGE AVE. FORT COLLINS, CO.80522 ATTN: MIKE GEBO HOUSE OF RALPH KIEL, 825 EAST LAUREL ST. FORT COLLINS AFTER REVIEWING THE HOUSE WITH THE OWNER THE FOLLOWING CONDITIONS WERE CORRECTED. A GFI RECEPTACLE WAS INSTALLED IN THE FIRST FLOOR KITCHEN, AND WAS SO MARKED OPEN GROUND. SMOKE DETECTORS WERE CHECKED, THE OWNER TO REPLACE THE BATTERIES. GFI RECEPTACLE WAS 'INSTALLED IN THE FIRST FLOOR BATHROOM. IN THE LOWER UNIT A JUNCTION BOX WAS INSTALLED IN THE LOWER BATHROOM CEILING. I SUGGESTED THAT GFI PROTECTION BE PLACED ON ALL BATHROOM AND KITCHEN DEVICES. NO ACTION WAS TAKEN ON THIS AS OF THIS TIME. I ALSO LOOKED AT INSTALLING BASEBOARD HEAT TO THE FIRST FLOOR UNIT, TO REPLACE THE FURNACE FROM HEATING THE AREA. THIS PROJECT WILL BE QUITE INVOLVED. THERE ARE A FEW ITEMS THAT NEED TO BE ADDRESSED. TIM SERVICE DISCONNECTING MEANS IS LOCATED IN THE FIRST FLOOR UNIT. THE DISCONNECTIlNIG MEANS MUST BE IN A LOCATION ALLOWING ALL OCCUPANTS ACCESS (NEC230.72C). THE BREAKER PANEL NOW IS OVER FULL. THERE ARE CONDUCTORS DOUBLED UP AT THE BREAKER SIDE. I AM SUGGESTING THAT A NEW SERVICE BE INSTALLED AFTER THE METER. JOHN A. MOE A-J ELECTRIC 1108 GREENBRIAR DR, FORT COLLINS CO. 80524 970-493-8232 970-367-7499