CITY OF FORT COLLINS INSPECTION DEPT.
281 NORTH COLLEGE AVE.
FORT COLLINS, CO.80522
ATTN: MIKE GEBO
HOUSE OF RALPH KIEL, 825 EAST LAUREL ST. FORT COLLINS
AFTER REVIEWING THE HOUSE WITH THE OWNER THE FOLLOWING CONDITIONS WERE
CORRECTED. A GFI RECEPTACLE WAS INSTALLED IN THE FIRST FLOOR KITCHEN, AND
WAS SO MARKED OPEN GROUND. SMOKE DETECTORS WERE CHECKED, THE OWNER TO
REPLACE THE BATTERIES. GFI RECEPTACLE WAS 'INSTALLED IN THE FIRST FLOOR
BATHROOM. IN THE LOWER UNIT A JUNCTION BOX WAS INSTALLED IN THE LOWER
BATHROOM CEILING.
I SUGGESTED THAT GFI PROTECTION BE PLACED ON ALL BATHROOM AND KITCHEN
DEVICES. NO ACTION WAS TAKEN ON THIS AS OF THIS TIME.
I ALSO LOOKED AT INSTALLING BASEBOARD HEAT TO THE FIRST FLOOR UNIT, TO
REPLACE THE FURNACE FROM HEATING THE AREA. THIS PROJECT WILL BE QUITE
INVOLVED. THERE ARE A FEW ITEMS THAT NEED TO BE ADDRESSED. TIM SERVICE
DISCONNECTING MEANS IS LOCATED IN THE FIRST FLOOR UNIT. THE DISCONNECTIlNIG
MEANS MUST BE IN A LOCATION ALLOWING ALL OCCUPANTS ACCESS (NEC230.72C). THE
BREAKER PANEL NOW IS OVER FULL. THERE ARE CONDUCTORS DOUBLED UP AT THE
BREAKER SIDE.
I AM SUGGESTING THAT A NEW SERVICE BE INSTALLED AFTER THE METER.