HomeMy WebLinkAbout1320 REEVES DR - DISCLOSURES - 11/21/2002Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 11/21/02 (970)377-1056 CUSTOMER: US Homes � 1320 Reeves Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 26500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 55 120 1888 —0.6 Ring A 47 115 1849 1.1 Ring A 40 106 1776 1.0 Ring A 35 95 1682 —1.2 Ring A 26 80 1545 —2.6 Ring A 20 77 1516 1.9 Ring A Correlation Coefficient r = .9848 Results: Flow Coefficient C = 721.75 Air Flow @ 50 Pascals : 1856 CFM50 +/— 1.0% 4.20 ACH50 (Air Changes Per Hour) Exponent n = 0.241 Effective Leakage Area (LBL) = 285.93 Square Inches +/— Equivalent Leakage Area (CANADA) = 369.52 Square Inches +/— Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 137 CFM = 68.4 CFM/OCCUPANT = 0.31 AIR CHANGES PER HOUR Na m 4.8% 2.9%