HomeMy WebLinkAbout614 E VINE DR - SPECIAL INSPECTIONS - 8/27/2003/04-- 3 30 36 77 August 27, 2003 Larimer County Fleet Management P.O. Box 1190 Fort Collins, Colorado 80522 Attention: Mr. John Shepek Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 Re: Construction Materials Compliance Summary Larimer County AST Installation; Building Permit No. B0303677 614 East Vine Fort Collins, Colorado Project No. 20027044 Dear Mr. Shepek: Earthwork At your request, we reviewed the earthwork materials placed and monitored during construction of the AST pad by Terracon on an "as requested" basis. Our services on the project building have included performing laboratory testing of the soils for suitability to the project specifications and the Geotechnical Engineering Report recommendations (Job No. 03-011) performed by Koechlein Consulting Geotechnical Engineers (dated April 3, 2003). As recommended in the soils investigation, on -site or approved imported soils were suitable for placement during construction. Laboratory tests indicated fill material tested by Terracon met the recommendations as outlined in the geotechnical report. The results of the field and laboratory testing were forwarded for review. In addition, the on -site superintendent and subcontractors were informed on a daily basis of the test results performed. Terracon performed 12 in -place density/compaction tests for the AST site subgrade and fill placement. The tests at the locations indicated met or ultimately achieved (after retesting) the compaction specification requirements. Observation of construction procedures, and physical in -place testing was provided by Terracon personnel on a part-time, as -requested basis. Based upon the limited tests and observations performed, results indicate suitable materials and specified compaction at the locations tested. Our test results represent only the materials at the location and time of testing. Terracon did not direct nor control the fill placement and compaction at the site and does not assume responsibility for the placement, compaction or control of the fill materials. Areas of fill which are not representative of our testing may exist, particularly in common fill areas such as slopes or landscaped outside of proposed construction. The foundation type and specific design for each structure will be recommended based on the particular characteristics of the soil type at foundation depth, and on the basis of further evaluations and observations prior to construction. Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com Larimer County AST Installation Compliance Summary Project No. 20027044 Page 2 Concrete The Portland cement concrete placed and tested on -site consisted property and compressive strength tests. The reports indicate compressive strength requirements for the project have been achieved. Reinforcing Steel 264�3 lferracon of 2 tests for physical the specified minimum Terracon provided reinforcing steel placement observation in structural concrete placements as requested. The observations were performed per the provided plans and specifications for the project and have been formally reported to the client and designated parties. Foundation Terracon provided observation of the foundation excavations as requested during construction. A summary of the observations and structural review response items were provided in written reports upon completion. Per the project geotechnical report and observations performed, the foundation has been placed in general accordance with the plans and specifications and were placed on the anticipated bearing material identified in our geotechnical report. This report has been prepared for the exclusive use of providing test data and observations to document the earthwork, concrete, and foundation operations conducted for the proposed project. The opinions and conclusions presented have been derived in accordance with generally accepted geotechnical and material engineering practice. No other warranty expressed or implied is made. In the event that there are any changes in the nature or design of the project, the conclusions contained in this report shall not be considered valid unless this firm reviews such changes, and the conclusions of this report are modified or verified in writing. This letter is prepared for the exclusive use and reliance of our client. Use or reliance by any other party is prohibited without the written authorization of our client and Terracon. Reliance on this letter by the client and all authorized parties will be subject to the terms, conditions and limitations stated in the proposal, report and Terracon's Terms and Conditions. The limitation of liability defined in the Terms and Conditions is the aggregate limit of Terracon's liability to the client and all relying parties. '/'�y F- �1; e�e_ 3 �3 Larimer County AST Installation Compliance Summary Project No. 20027044 Page 3 lferracon It has been our pleasure to work with you on this project and to continue providing services during your ongoing construction. Should you have any questions, or need additional information, please contact us at your convenience. Respectfully submitted, TERRACON Mike L Walker, CET Manager of Construction Services Dean R. Parson, P.E. �,jz�/o3 Associate Principal/ co, P�e No "t $qv;S Terry Stahr, E.I. Project Engineer End/Copies to: (2) Addressee (1) Padilla Construction (1) City of Fort Collins Building Department MLW/DRP