HomeMy WebLinkAbout432 PLOWMAN WAY - DISCLOSURES - 10/30/2002Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 10/30/02 (970)377-1056 CUSTOMER: Kaufman and Broad 432 Plowman Way Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 17898 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 50 1224 —1.5 Ring A 53 45 48 1200 0.7 Ring A 40 41 1110 0.5 Ring A 33 37 1055 0.9 Ring A 27 31 967 1.1 Ring A 24 852 —2.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9949 C = 188.21 n = 0.465 Results: Air Flow @ 50 Pascals 1159 CFM50 +/— 0.7% 3.89 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 101.63 Square Inches +/— 5.7% Equivalent Leakage Area (CANADA) = 161.16 Square Inches +/— 3.5% Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) 95 CFM = 47.5 CFM/OCCUPANT = 0.32 AIR CHANGES PER HOUR